咨询热线:021-80392549
发布信息

贺德克温度开关 ETS 3200 温度开关

点击图片查看原图
品牌: 贺德克温度传感器
单价: 面议
所在地: 上海
有效期至: 长期有效
最后更新: 2024-06-09 12:13
浏览次数: 816
询价
店铺基本资料信息
产品详细说明

ETS 3200是一款具有数字显示的紧凑型电子温度开关。

凭借其集成的温度探头,ETS 3200特别适合直接油箱安装,并有多种长度可供选择。

具有一个或两个开关输出和可选的附加模拟输出信号的不同输出版本,提供了多种应用可能性。

使用按键板可以非常快速和轻松地调整开关点和相关的滞后。

Specifications

Type

Electronic Temperature Switch

Model Code De script ion

ETS 3226-2-018-000

Direct Current (DC) Supply Voltage When Applied According to UL Specifications (Without Analog Output)

9 to 35 V

Note for Direct Current (DC) Supply Voltage When Applied According to UL Specifications

Limited energy - According to 9.3 UL 61010; Class 2; UL 1310/1585; LPS UL 60950

Maximum Current Consumption (With Inactive Switching Output)

35 mA

Maximum Current Consumption (With Inactive Switching Output and Analog Output)

55 mA

Display

4-Digit, LED, 7 Segment, Red, Height of Digits 7 mm

Weight

~135 g

Material of Connection

Stainless Steel

Seal Material

Fluoroelastomer (FKM)

Maximum Output Permitted Load Resistance

500

Minimum Output Permitted Load Resistance

1 k

Switching Function

Switching direction of the switching outputs adjustable (N/C or N/O)

Electrical Connection

Male M12x1, 4 Pole

CUL?US Mark

Certificate No.: E318391

Note for CUL?US Mark

Environmental conditions according to 1.4.2 UL 61010-1; C22.2 No. 61010-1

Switch Point

-23 to 100 ?C-9 to 212 ?F

Hysteresis (Switch Point)

1.0 to 123.5 ?C2 to 222 ?F

Residual Ripple of Supply Voltage

≤ 5 %

Increment (Switch Point)

0.5 ?C1.0 ?F

Note for Increment (Switch Point, Window Function)

  • According to customer specification
  • xxxxxxxxxxxxxxxxx" style="box-sizing: inherit; border: 1px solid rgb(0, 170, 184); background: rgb(0, 170, 184); color: rgb(255, 255, 255); border-radius: 10px; width: 17px; float: left; margin: 5px;">
    All ranges given in the table can be adjusted by the increments shown.

    Lower Switch Value (Window Function)

    -23 to 97.5 ?C-9 to 208 ?F

    Upper Switch Value (Window Function)

    -22 to 98.5 ?C-7 to 209 ?F

    Increment (Window Function)

    0.5 ?C1.0 ?F

    Maximum Total Current Consumption

    2.455 A

    Modification Number

    000

    Switching Outputs

    2 Switching Outputs

    Division

    17

    BUn

    EA

    Input Data

    Measuring Range

    -25 to 100 ?C-13 to 212 ?F

    Input Probe Length

    0.71 in18 mm

    Input Pressure Resistance

    8700 psi

    Input Mechanical Connection

    G1/2 A DIN 3852 (Male)

    Torque Value

    45 N·m33 lb·ft

    Input Mechanical Connection Type

    G1/2 A DIN 3852, Male

    Input Mechanical Connection Size

    G1/2, Male

    Output Data

    Accuracy at Room Temperature

    ≤ ± 2.0?F (+/- 1.0?C)

    Operating Temperature [Min]

    -25 ?C-13 ?F

    Operating Temperature [Max]

    100 ?C212 ?F

    Output Temperature Drift at Maximum Zero Point and Range (Full Scale)

    ≤ ± 0.0085% %/°F

    Switch Outputs

    Switch Outputs Type

    PNP Transistor Switching Output

    Maximum Switching Current Per Switch Output

    1.2 A

    Switching Cycles In Million

    > 100 million

    Rise Time to DIN EN 60751 for t50

    3 s

    Rise Time to DIN EN 60751 for t80

    9 s

    Environmental Conditions

    Ambient Temperature Range

    -13 to 140 ?F

    Ambient Temperature Range

    -13 to 176 ?F

    Sensing Temperature [Max]

    100 ?C212 ?F

    Sensing Temperature [Min]

    -25 ?C-13 ?F

    Storage temperature range

    -40 to 176 ?F

    Fluid temperature range

    -13 to 212 ?F

    Note for Fluid Temperature Range

    -13 °F with FPM seal, -40 ?F on request

    CE Mark

    CE Mark EN 61000-6-1/2/3/4

    Vibration Resistance According to DIN EN 60068-2-6 at 0 to 500 Hz

    ≤ 10 g

    Shock Resistance According to DIN EN 60068-2-29 (11 ms)

    ≤ 50 g

    Protection class to IEC 6529

    IP 67

    Pin Connections

    Pin Connection 1

    +UB

    Pin Connection 2

    SP2

    Pin Connection 3

    0 Voltage

    Pin Connection 4

    SP1

    Dimensions

    Sensor Diameter

    6 mm

    Sensor Length

    18 mm

    Length

    42 mm

    Width

    40.4 mm

    Setting Options

    All the settings available on the ETS 3200 are combined in 2 easy-to navigate menus. To prevent unauthorized adjustment of the instrument, a programming lock can be set.

    Additional Information

    For optimum adaptation to the particular application, the instrument has many additional adjustment parameters (e.g. switching delay times, N/C / N/O function, etc.).

    Accessories

    Appropriate accessories, such as electrical connectors, protective sleeves for tank mounting, splash guards, etc. can be found in the Accessories brochure.

    Special Features

    • 2 switching outputs, up to 1.2 A load per output.
    • Optional analog output signal selectable (4 .. 20 mA, 0 .. 10 V)
    • 4-digit display
    • Optimum alignment - display can be rotated in two planes (axes)
    • Switching / switch-back points and many useful additional functions can be set using the keypad.
    • Display of temperature and unit of measurement in ?C or ?F
    • Switching mode of the switching outputs adjustable (switching point function or window function)
    • Switching direction of the switching outputs adjustable (N/C or N/O)
    • Switch-on and switch-off delay adjustable from 0.00 .. 99.99 seconds
    • Choice of display (actual temperature, peak temperature, switching point 1, switching point 2, display off)

    Note

    Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.

    Subject to technical modifications.

    更多贺德克产品请咨询贺德克电气服务商http://hydac.m.eepottsltd.com/

    Baidu
    map