The SERIES 616KD Differential Pressure Transmitters with One-Touch® Digital Push- Button Calibration Technology are designed for simplicity, making them the ideal choice for installers and maintenance professionals. These instruments not only alleviate cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instruments during calibration. With single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required. No additional reference pressure sources or separate calibration devices are necessary.
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: 616KD-A: ±0.25% FS; 616KD-B: ±1% FS, 616KD-C: ±2% FS.
Stability: ±1% FS/year.
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Pressure Limits: 2 psig (ranges 5" w.c. or lower); 5 psig (ranges 10 to 40" w.c.).
Thermal Effect: 616KD-A: ±0.02% FS/°F; 616KD-B: ±0.04% FS/°F; 616KD-C: ±0.06% FS/°F, includes zero and span.
Power Requirements: 4 to 20 mA output: 10 to 35 VDC (2-wire) or 12 to 26 VAC (4-wire); 5 V output: 10 to 35 VDC (3-wire) or 12 to 26 VAC (4-wire); 10 V output: 13 to 35 VDC (3-wire) or 12 to 26 VAC (4-wire).
Output Signal: 4 to 20 mA or option with field selectable 0 to 10, 0 to 5, 2 to 10, 1 to 5 V.
Zero and Span Adjustments: Push button.
Loop Resistance: 4 to 20 mA output (DC): 0 to 1250 Ω max. Rmax = 50(VpsDC -10) Ω; 4 to 20 mA output (AC): 0 to 1200 Ω max. Rmax = 50(1.4 VpsAC -12) Ω; Voltage output: 5K Ω minimum.
Current Consumption: 24 mA max.
Electrical Connections: Screw-type terminal block.
Process Connections: Barbed, dual size to fit 1/8" & 3/16" (3 mm and 5 mm) ID rubber or vinyl tubing.
Enclosure Rating: NEMA 1 (IP20).
Mounting Orientation: Vertical with pressure connections pointing down.
Weight: 1.8 oz (51 g).
Agency Approval: CE.
Compensated Temperature Range: 20 to 122°F (-6.67 to 50°C).
Warm Up time: 20 minutes.