Brand new is the flexibility through switchable measurement ranges and an integrated broad-range power supply.
ProLine P 51000 at a glance
Overload protected current measurement via shunt resistor from amps to kiloamps
4800 V AC/DC protection at PD3, OV3 according to EN 50124-1, UL 347
18 kV AC test voltage
Particularly low measurement error < 0.1 % of meas. value + 0.1 % f.s
Floating standard signal output (switchable: 0/4 ... 20 mA, 0 ... 10 V) and additional monitoring output
Integrated broad-range power supply (16.8) 24 to 230 (253) V DC/AC
Fire and smoke: hazardous level HL3 to EN 45545-2:2016
Suited for use on railway vehicles: EN 50125-1/-2 and EN 50155
RAMS: diagnostics contact for device status, MTBF 155/38 years (ground benign/ground mobile)
Resistant against vibration and mechanical shock to EN 61373 (railway applications)
EMC to EN 50121-1, EN 50121-3-2 (railway applications) and EN 61326-1 (industrial applications)
Contact protection through protective cover, housing with IP protection up to IP54 (HV side), IP33 (LV side)
Suited for energy measurement to EN 50463-2 (1.0 R)
Isolation coordination to EN 50124-1, EN 50123-1 (railway) and EN 50178, UL 347 (industry)