安全标准:符合UL1950认可
产品应用:*数据/信息处理设备
RTW系列通用规范:
1 |
Rated output DC voltage |
(1) |
5V |
(2) |
+12V |
(3) |
-12V |
(1) |
5V |
(2) |
+15V |
(3) -15V |
||
2 |
Rated output DC current |
6A |
5A |
1A |
4A |
4A |
1A |
|||||||
3 |
Maximum output power |
102W |
105W |
|||||||||||
4 |
Efficiency(120/230VAC,TYP) |
*1 |
80.3% / 80.6% |
|||||||||||
5 |
Input current |
*1 |
1.3A (100VAC), 0.6A (230VAC) |
|||||||||||
6 |
Power factor |
*1 |
0.99 TYP (100VAC), 0.97 TYP (230VAC) |
|||||||||||
7 |
Inrush current |
*2 |
21Apk MAX (120VAC), 42Apk MAX (240VAC) |
|||||||||||
8 |
Initial setting accuracy |
*1 |
±0.5% MAX(5V,+12V,+15V), ±5% MAX(-12V,-15V) |
|||||||||||
9 |
Maximum ripple noise |
50mVpp(5V load), 70mVpp(±12V, ±15V load) |
||||||||||||
10 |
Maximum line regulation |
±0.1% |
||||||||||||
11 |
Maximum load regulation |
±0.5%(5V load), ±0.2%(±12V, ±15V load) |
||||||||||||
12 |
Voltage tolerance ratio |
±3% at line, load, time, temperature |
||||||||||||
13 |
Hold-up time |
*1 |
20ms MiN after last AC line peak |
|||||||||||
14 |
Over current protection |
*3 |
more than 105% A of rated current |
|||||||||||
15 |
Over voltage protection |
*4 |
5.75V ~ (Detected 5V output) |
|||||||||||
16 |
Dimensions |
105(W) 190(D) 42(H) mm / 4.13"(W) 7.48"(D) 1.65"(H) |
||||||||||||
17 |
Weight |
740g / 1.63lb. TYP |