ITEM |
|
|
1 |
Maximum line / load regulation |
±0.5% |
|
2 |
Voltage tolerance ratio |
±3% at line, load, time, temperature |
|
3 |
Operating temperature |
-10 ~ 60℃ (Refer to Output derating) |
|
4 |
Operating humidity |
30 ~ 90%RH (Non condensing) |
|
5 |
Storage temperature |
-30 ~ 85℃ |
|
6 |
Storage humidity |
10 ~ 95%RH (Non condensing) |
|
7 |
Cooling |
Convection or forced air cooling (Refer to Output derating) |
8 |
Electric strength voltages |
Input - Output 3000VAC 1 minute , Input - FG 1500VAC 1 minute , Output - FG 500VAC 1 minute |
9 |
Insulation resistance |
100MΩ MIN DC500V 25℃ 70%RH Input - Output, Input - FG, Output - FG |
10 |
Leakage current |
0.5mA MAX (240VAC, 50Hz) |
|
11 |
Vibration |
10~55Hz 2G (3 directions each 1 hour) |
|
12 |
Shock |
20ms 20G (3 directions each 3 times) |
|
13 |
Safety standards |
UL1950, CSA950(cUL), EN60950(NEMKO) Approvals |
14 |
Conduction noise |
Meeting FCC Class B, EN55022 Class B, VCCI Class B |
15 |
Harmonic distortion |
Meeting EN61000-3-2 |
|
16 |
Mains surge |
Meeting EN61000-3-5 Level 3/4KV(CM),2KV(DM) |
|
17 |
Dimensions |
83(W) 170(D) 35(H) mm / 3.27"(W) 6.7"(D) 1.38"(H) |
|
18 |
Weight |
450g / 0.99lb. TYP |
|